The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt

Sambit Kumar Pattanayak, Maheswar Chaudhury, Bikash Parida.


Abstract
Objective: The study aims to assess the technical and clinical results of the transjugular intrahepatic portosystemic shunt (TIPS) procedure carried out under additional transabdominal ultrasound guidance.
Methods: We evaluated the radiation dosage for all TIPS performed with transabdominal ultrasound guidance for PV puncture over four years (n=212, with 210 completed and data available for 206); fluoroscopy time, dose area product (DAP), and skin dose were recorded.
Results: The mean fluoroscopy time was 12 minutes and 9 seconds (SD, 14 minutes and 38 seconds), the mean DAP was 40.3 ± 73.1 Gy.cm2, and the mean skin dosage was 404.3 ± 464.8 mGy.
Conclusion: Our findings show that ultrasound-guided PV puncture yields fluoroscopy times and radiation doses significantly lower than the solely published dose reference limits.

Key words: transjugular intrahepatic portosystemic shunt, fluoroscopic, ultrasound


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Sambit Kumar Pattanayak
Articles by Maheswar Chaudhury
Articles by Bikash Parida
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Pattanayak SK, Chaudhury M, Parida B. The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt. Int J Med Rev Case Rep. 2022; 6(10): 69-72. doi:10.5455/IJMRCR.172-1658311422


Web Style

Pattanayak SK, Chaudhury M, Parida B. The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt. https://www.mdpub.net/?mno=84661 [Access: April 05, 2024]. doi:10.5455/IJMRCR.172-1658311422


AMA (American Medical Association) Style

Pattanayak SK, Chaudhury M, Parida B. The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt. Int J Med Rev Case Rep. 2022; 6(10): 69-72. doi:10.5455/IJMRCR.172-1658311422



Vancouver/ICMJE Style

Pattanayak SK, Chaudhury M, Parida B. The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt. Int J Med Rev Case Rep. (2022), [cited April 05, 2024]; 6(10): 69-72. doi:10.5455/IJMRCR.172-1658311422



Harvard Style

Pattanayak, S. K., Chaudhury, . M. & Parida, . B. (2022) The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt. Int J Med Rev Case Rep, 6 (10), 69-72. doi:10.5455/IJMRCR.172-1658311422



Turabian Style

Pattanayak, Sambit Kumar, Maheswar Chaudhury, and Bikash Parida. 2022. The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt. International Journal of Medical Reviews and Case Reports, 6 (10), 69-72. doi:10.5455/IJMRCR.172-1658311422



Chicago Style

Pattanayak, Sambit Kumar, Maheswar Chaudhury, and Bikash Parida. "The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt." International Journal of Medical Reviews and Case Reports 6 (2022), 69-72. doi:10.5455/IJMRCR.172-1658311422



MLA (The Modern Language Association) Style

Pattanayak, Sambit Kumar, Maheswar Chaudhury, and Bikash Parida. "The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt." International Journal of Medical Reviews and Case Reports 6.10 (2022), 69-72. Print. doi:10.5455/IJMRCR.172-1658311422



APA (American Psychological Association) Style

Pattanayak, S. K., Chaudhury, . M. & Parida, . B. (2022) The effect of transabdominal ultrasound-guided transjugular portal venous puncture on radiation exposure in the establishment of a transjugular intrahepatic portosystemic shunt. International Journal of Medical Reviews and Case Reports, 6 (10), 69-72. doi:10.5455/IJMRCR.172-1658311422