E-ISSN 2534-9821
 

Original Research
Online Published: 08 May 2022
 


Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls

Malvika Sharma, Dinesh Gupta, Surbhi Kapoor, Narain Sharma.


Abstract
Introduction:
Pseudoexfoliation in the eye is diagnosed by the presence of white, flaky, dandruff-like fibrillo granular material on the pupillary margin or the anterior capsule of the lens. A characteristic “three-ring sign” is noted on the anterior lens capsule after pupillary dilatation. The presence of pseudoexfoliation (PEX) material in the anterior stromal layers of the cornea and a decrease in the stromal cell densities have been suggested to be the cause of thinner CCT in eyes with PEX. The thinning is presumed to be due to apoptosis of the keratocytes. Aim: To evaluate Central Corneal Thickness in patients with pseudo-exfoliation syndrome and compare them with normal healthy controls. Material & Methods: The proposed case-control hospital-based study comprised 100 participants divided into two groups: Group I: Patients above 40 years of age diagnosed with pseudoexfoliation syndrome on Slit lamp examination. Group II: Healthy individuals above 40 years of age without pseudoexfoliation syndrome. Informed written consent was taken from all participants. Other ophthalmic or systemic conditions which influence the corneal thickness measurement like Corneal dystrophies, degenerations, scars and post corneal refractive surgery, previous ocular surgery or ocular trauma, Glaucoma, Ocular hypertension, Uveitis, Systemic diseases like diabetes, or with ocular manifestations (collagen, skin, mucous membrane diseases), usage of topical medications which might affect the corneal conditions (esp. medications with preservatives), were excluded from the study. After a comprehensive ophthalmic examination, specular microscopy was performed on all study participants using TOPCON SP-1P Specular microscope to record central corneal thickness. Results: The mean Central Corneal Thickness (µm) obtained from specular microscopy in the PEX group was 487.34±27.16, while in controls, the mean Central Corneal Thickness (µm) recorded using specular microscopy was 505.09±26.36. The comparison of CCT (µm) between the PEX group and the Control group was statistically significant (p-value <0.0001). Conclusion: Pseudoexfoliation syndrome significantly affects the Central Corneal Thickness.

Key words: Pseudoexfoliation Syndrome, Central Corneal Thickness, Specular Microscopy


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Malvika Sharma
Articles by Dinesh Gupta
Articles by Surbhi Kapoor
Articles by Narain Sharma
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Sharma M, Gupta D, Kapoor S, Sharma N. Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls. Int J Med Rev Case Rep. 2022; 6(11): 20-22. doi:10.5455/IJMRCR.172-1646158146


Web Style

Sharma M, Gupta D, Kapoor S, Sharma N. Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls. https://www.mdpub.net/?mno=95828 [Access: October 14, 2024]. doi:10.5455/IJMRCR.172-1646158146


AMA (American Medical Association) Style

Sharma M, Gupta D, Kapoor S, Sharma N. Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls. Int J Med Rev Case Rep. 2022; 6(11): 20-22. doi:10.5455/IJMRCR.172-1646158146



Vancouver/ICMJE Style

Sharma M, Gupta D, Kapoor S, Sharma N. Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls. Int J Med Rev Case Rep. (2022), [cited October 14, 2024]; 6(11): 20-22. doi:10.5455/IJMRCR.172-1646158146



Harvard Style

Sharma, M., Gupta, . D., Kapoor, . S. & Sharma, . N. (2022) Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls. Int J Med Rev Case Rep, 6 (11), 20-22. doi:10.5455/IJMRCR.172-1646158146



Turabian Style

Sharma, Malvika, Dinesh Gupta, Surbhi Kapoor, and Narain Sharma. 2022. Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls. International Journal of Medical Reviews and Case Reports, 6 (11), 20-22. doi:10.5455/IJMRCR.172-1646158146



Chicago Style

Sharma, Malvika, Dinesh Gupta, Surbhi Kapoor, and Narain Sharma. "Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls." International Journal of Medical Reviews and Case Reports 6 (2022), 20-22. doi:10.5455/IJMRCR.172-1646158146



MLA (The Modern Language Association) Style

Sharma, Malvika, Dinesh Gupta, Surbhi Kapoor, and Narain Sharma. "Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls." International Journal of Medical Reviews and Case Reports 6.11 (2022), 20-22. Print. doi:10.5455/IJMRCR.172-1646158146



APA (American Psychological Association) Style

Sharma, M., Gupta, . D., Kapoor, . S. & Sharma, . N. (2022) Comparison of Central Corneal Thickness in patients with Pseudoexfoliation Syndrome v/s Controls. International Journal of Medical Reviews and Case Reports, 6 (11), 20-22. doi:10.5455/IJMRCR.172-1646158146