E-ISSN 2534-9821
 

Original Research

Online Publishing Date:
08 / 08 / 2022

 


Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia

Chhaya M Suryawanshi, Khalki Saravan Kumar, Sonalika Tudimilla.


Abstract
Background: Obtunding, the hemodynamic responses during laryngoscopy and intubation, remains a major concern for anesthesiologists. The present study compared the haemodynamic changes and glottic visualization during intubation between C-MAC, Mc Coy and Macintosh Laryngoscopes.
Methods: We conducted the study on 150 patients under ASA I or ASA II scheduled for elective surgery. The patients were randomly assigned to one of the three groups containing 50 patients using a computer-generated random allocation chart. The intubation was performed with Group-A (Macintosh), Group-B (McCoy) and Group-C (C-MAC). Hemodynamic variables such as Heart rate, Systolic blood pressure, diastolic blood pressure, and mean arterial pressure were recorded before, during and till 5 minutes post-intubation, and glottis opening was assessed with Cormack Lehane grading.
Observations and Conclusion: There was a statistically significant increase in hemodynamic parameters during laryngoscopy and intubation of patients of all three study groups. Still, less increase in hemodynamic responses was observed in patients intubated with McCoy laryngoscope compared to those intubated with Macintosh and C Mac laryngoscope. The C Mac laryngoscope shows better visualization of the glottis when compared to that of Macintosh and McCoy.

Key words: Airway, laryngoscopes, hemodynamics


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Chhaya M Suryawanshi
Articles by Khalki Saravan Kumar
Articles by Sonalika Tudimilla
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Suryawanshi CM, Kumar KS, Tudimilla S. Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia. Int J Med Rev Case Rep. 2022; 6(10): 27-32. doi:10.5455/IJMRCR.172-1646671453


Web Style

Suryawanshi CM, Kumar KS, Tudimilla S. Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia. https://www.mdpub.net/?mno=99105 [Access: April 04, 2024]. doi:10.5455/IJMRCR.172-1646671453


AMA (American Medical Association) Style

Suryawanshi CM, Kumar KS, Tudimilla S. Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia. Int J Med Rev Case Rep. 2022; 6(10): 27-32. doi:10.5455/IJMRCR.172-1646671453



Vancouver/ICMJE Style

Suryawanshi CM, Kumar KS, Tudimilla S. Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia. Int J Med Rev Case Rep. (2022), [cited April 04, 2024]; 6(10): 27-32. doi:10.5455/IJMRCR.172-1646671453



Harvard Style

Suryawanshi, C. M., Kumar, . K. S. & Tudimilla, . S. (2022) Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia. Int J Med Rev Case Rep, 6 (10), 27-32. doi:10.5455/IJMRCR.172-1646671453



Turabian Style

Suryawanshi, Chhaya M, Khalki Saravan Kumar, and Sonalika Tudimilla. 2022. Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia. International Journal of Medical Reviews and Case Reports, 6 (10), 27-32. doi:10.5455/IJMRCR.172-1646671453



Chicago Style

Suryawanshi, Chhaya M, Khalki Saravan Kumar, and Sonalika Tudimilla. "Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia." International Journal of Medical Reviews and Case Reports 6 (2022), 27-32. doi:10.5455/IJMRCR.172-1646671453



MLA (The Modern Language Association) Style

Suryawanshi, Chhaya M, Khalki Saravan Kumar, and Sonalika Tudimilla. "Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia." International Journal of Medical Reviews and Case Reports 6.10 (2022), 27-32. Print. doi:10.5455/IJMRCR.172-1646671453



APA (American Psychological Association) Style

Suryawanshi, C. M., Kumar, . K. S. & Tudimilla, . S. (2022) Comparative study of hemodynamic response and glottic view to laryngoscopy and endotracheal intubation with Macintosh, McCoy blades and X-mac video laryngoscopy in patients undergoing general anaesthesia. International Journal of Medical Reviews and Case Reports, 6 (10), 27-32. doi:10.5455/IJMRCR.172-1646671453